Engineered laminate of S2-449/PR 381 Tape, stacked [+-45/0/+-45]:s. Properties here are laminate-level effective values in the laminate's own axes — not the lamina constants, which live on the parent prepreg (S2-449/PR 381 Tape). From MIL-HDBK-17-2F Volume 2 (US Government work, public domain).
Compliance & Regulations
Fiber Direction
Ply Schedule
Laminate Code
[45/-45/0/45/-45/-45/45/0/-45/45]s
Fiber angles relative to the 0° reference direction (red arrow in 3D view). 0° = longitudinal, 90° = transverse, ±45° = shear paths.
| Property | Value | Unit | Conditions | Source | |
|---|---|---|---|---|---|
Compressive Modulus(Ec) | 6,760 range 6,540–6,940n=10, 2 batches, CV 1.74% | ksi | 82°C · compressive · ETA · 1-axis · [0]:5 · norm. thk+FAW | ||
Compressive Strength(σc) | 146 range 131–157n=10, 2 batches, CV 5.27% | ksi | 71°C · compressive · ETW · 1-axis · [0]:5 · as-measured | ||
Elongation at Break(εf) | 0.4300 range 0.3800–0.4800 | % | -54°C · CTA · 2-axis · [90]:10 · as-measured | ||
Interlaminar Shear Strength(ILSS) | 7.200 range 7.000–7.400n=13, 2 batches, CV 1.7% | ksi | 71°C · shear · ETW · 13-axis · [0]:12 · as-measured | ||
Shear Modulus(G) | 555 range 541–578n=10, 2 batches, CV 2.26% | ksi | 82°C · shear · ETA · 12-axis · [+-45]:2s · as-measured | ||
Ultimate Shear Strength(Fsu) | 9.500 range 9.000–9.800n=12, 2 batches, CV 2.9% | ksi | 71°C · shear · ETW · 12-axis · [+-45]:2s · as-measured | ||
Ultimate Tensile Strength(σUTS)2 entries | 69.50 range 66.70–71.30n=10, 2 batches, CV 2.18% | ksi | 23°C · RTA · x-axis · [+-45/0/+-45]:s · norm. thk+FAW | ||
| ↳ | 72.90 range 71.40–75.60n=10, 2 batches, CV 1.67% | ksi | 23°C · RTA · x-axis · [+-45/0/+-45]:s · as-measured | ||
Young's Modulus(E)2 entries | 2,870 range 2,780–2,960n=10, 2 batches, CV 2.21% | ksi | 23°C · RTA · x-axis · [+-45/0/+-45]:s · norm. thk+FAW | ||
| ↳ | 3,010 range 2,940–3,110n=10, 2 batches, CV 1.58% | ksi | 23°C · RTA · x-axis · [+-45/0/+-45]:s · as-measured |
Reference data from cited sources. Not verified or certified by MatWorld Inc. Verify against the source before use in design. Terms: engineering data