Engineered laminate of T650-35 12K/976 unidirectional tape, stacked [90/0]:8. Properties here are laminate-level effective values in the laminate's own axes — not the lamina constants, which live on the parent prepreg (T650-35 12K/976 unidirectional tape). From MIL-HDBK-17-2F Volume 2 (US Government work, public domain).
Compliance & Regulations
Fiber Direction
Ply Schedule
Laminate Code
[90/0/90/0/90/0/90/0/90/0/90/0/90/0/90/0]T
Fiber angles relative to the 0° reference direction (red arrow in 3D view). 0° = longitudinal, 90° = transverse, ±45° = shear paths.
| Property | Value | Unit | Conditions | Source | |
|---|---|---|---|---|---|
Compressive Modulus(Ec) | 59.64 – 77.22 | GPa | 6 entriesClick to expand | ||
Compressive Strength(σc) | 0.5323 – 1.124 | GPa | 9 entriesClick to expand | ||
Shear Modulus(G) | 5.137 range 4.688–5.723n=30, 5 batches, CV 4.82% | GPa | 22°C · RTA · 12-axis · [+/-45]:4s · as-measured | ||
Ultimate Shear Strength(Fsu) | 102.7 range 90.32–124.8n=30, 5 batches, CV 11.4% | MPa | 22°C · RTA · 12-axis · [+/-45]:4s · as-measured | ||
Ultimate Tensile Strength(σUTS) | 1.593 range 1.207–1.765n=32, 5 batches, CV 7.37% | GPa | 22°C · RTA · 1-axis · [0]:9 · norm. thk+FAW | ||
Young's Modulus(E) | 151.7 range 144.1–162.0n=32, 5 batches, CV 3% | GPa | 22°C · RTA · 1-axis · [0]:9 · norm. thk+FAW | ||